{"product_id":"cnc-2p-va-protection-device-63a-yc9-va","title":"CNC 2P VA Protection Device 63A YC9-VA","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eYC9VA voltage and current display relay is a microprocessor-based voltage monitoring device for single-phase AC networks to protect electrical equipment from surge voltage. The device analyzes the main voltage and displays its current value on a digital indicator. Load is switched by an electromagnetic relay. The user can set the current voltage value and delay time through the button. The value is stored in non-volatile memory. Aluminum wires and copper wires can be used for connection.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eYC9VA voltage and current display relay is used in administrative, industrial, and residential buildings and has the function of protecting single-phase lines:\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\"\u003eUndervoltage protection;\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eOvervoltage protection;\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eWorking under voltmeter mode;\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eOvercurrent protection.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" border=\"1\" class=\"MsoTable15Grid2Accent1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eData\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRated power supply voltage\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAC 230V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRated frequency\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e50\/60Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMaximum voltage adjustment range\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e230V-300V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eMinimum voltage adjustment range\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e120V-210V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRange of adjustment of the maximum current\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1A-63A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDeviation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMaximum action time\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u0026lt;275V: 0.1s; ≥275V: 0.02s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDelay time adjustment range\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1-90s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMinimum action time\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e0.5s (≥160V); \u0026lt;0.1s(\u0026lt;160V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDelay time adjustment range, overcurrent trip time\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1-90s (Inom \u0026lt; Islim \u0026lt; Imax); 0.1s (Islim ≥ Imax)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eVoltmeter accuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRated insulation voltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e400V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eOutput contact\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1NO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProtection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIP20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003ePollution\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eElectrical life\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100000 times\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMechanical life\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1000000 times\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAltitude\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e≤2000m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e-5°C~+40°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStorage temperature\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e-40°C~+55°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e50% at 40°C (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e35mm DIN rail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRange of adjustment of the on-delay time\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1-90s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen a voltage is applied to the device, the digital indicator will display the current value of the voltage in the network.\u003cbr\u003eA flashing light indicates that there is no voltage on the output of the device. If the supply voltage is within the set range, after \u003cb\u003eTon\u003c\/b\u003e (default is 30 seconds), the load will turn on and the indicator will stop flashing. If the voltage is not within the specified range, the load will not be connected to the line until the voltage returns to normal.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMeanwhile, if the voltage is lower than the set lower limit during the restart, the error indicator will flash. If the voltage is higher than the set upper limit, the error indicator will remain on.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eWiring Diagram\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/1933\/6262\/files\/Screenshot_2025-06-17_130706.png?v=1750147648\"\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Sultani.pk","offers":[{"title":"Default Title","offer_id":46481428742213,"sku":null,"price":4500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/7164\/1413\/files\/CNC_2P_VA_Protection_Device_63A.webp?v=1795028168","url":"https:\/\/sultani.pk\/products\/cnc-2p-va-protection-device-63a-yc9-va","provider":"SULTANI SOLAR ENERGY","version":"1.0","type":"link"}